  • QuantDat/nSens: Multi-sensor industrial transmitter for humidity and temperature probes.
  • ClimMate: Mobile reference measuring instrument for humidity and temperature in a set.
  • HygroGuard/ClimaLog/DataLog: Data logger systems with internal and external sensors.
  • HygroMaxx: HVAC-transmitter for humidity and temperature measurement with analogue outputs.
  • StatMaxx: HVAC-thermo-hygrostat with integrated relay switches.
  • TempMaxx: HVAC-temperature transmitter with integrated relay switch and analogue output.

  • Available models
    DKSH-Novasina-QuantaDat-nSens
    Technical Data
    Power supply
    24V +/- 15% AC or DC (galvanic isolated)
    Power consumption
    max. ca.3W
    Display
    Graphical display with LED backlight, 128 x 64 Pixel
    Selectable parameters
    Humidity; Temperature; Mixing ratio; Water vapour partial pressure; Dew-point temperature; Specific enthalpy; Absolute humidity
    Analogue outputs
    4 scalable & adjustable analogue outputs, 0/4..20mA or 0/2..10V
    Digital outputs
    RS-485 Version with relay: 2 relay contacts, switching power <=50V/2A/60W
    Housing material
    ABS - lid blue RAL 5014, bottom grey RAL 7035
    Protection class
    IP54
    Operating temperature
    0 to 50°C
    Storage temperature
    -10 to + 60°C (non-condensing)
    CE-/EMC compatibility
    Safety: IEC 61010-1:2010 EMC: IEC 61000-6-2:2005, EN 61000-6-2:2005 IEC: 61000-6-3:2006+A1:2010, EN 61000-6-3:2007+A1:2011

    Multi-sensor measurement system with intelligent and robust humidity/temperature sensors and analog signal exits.

    This cost-efficient solution allows the user to connect up to four external digital nSens-HT humidity and temperature sensors with one transmitter.

    Key Features:

    • Reduced costs per measuring point thanks to multi-sensor architecture
    • High accuracy, reproducible measurement, no detectable hysteresis
    • Linear and fast response up to the humidity saturation level
    • Automatic probe identification
    • Graphics and illuminated display
    • Exchangeable sensor with stored calibration data
    DKSH-Novasina-Humidity-Temperature-Measurement-ClimMate
    Operation / display unit
    ClimMate - multifunction handheld measuring instrument
    Power supply
    4 x 1.5VDC alkaline batteries or USB +5V power supply unit
    Power consumption
    approx. 400 mW, battery lifetime approx.1 year, confi gurable Auto-Off
    Display
    Graphic display TFT 240 x 320, capacitive touch display
    Dimensions / Weight
    External dimensions: W62 x D34 x H170 mm (without probe)
    Weight:
    approx. 200 gr
    Measuring parameters
    relative humidity; temperature (nSens-HT): accuracy see below abs.press. 800-1100mbar (integrated): accuracy @25°C +/-0.5mbar calculated parameters: mixing ratio; water vapor pressure; dew point temperature, abs. humidity; wet bulb temp.; water activity etc.
    Interfaces
    USB for connection to PC / UMB for connection of external probes
    Protection class
    IP54
    Operating temperature
    0 to 50°C
    Storage temperature
    -20 to +80° C

    Portable, battery-powered measuring and reference instrument for measurement of relative air humidity, temperature, absolute pressure, air velocity, air flow rate, C02 and water activity.

    Key Features:

    • Integrated data storage
    • Data visualizing software and SAL-SC humidity generator for calibration included in scope of delivery
    • Large, colour LCD-Touchscreen
    • Above average accuracy, reproducible measurement, no detectable hysteresis
    • Linear and fast response up to humidity saturation level
    • Intelligent, robust humidity/temperature sensor with stored calibration data
    DKSH-Novasina-HygroGuard-ClimaLog-DataLog
    HygroGuard 30
    ClimaLog 30
    DataLog 30
    Working range sensor
    rel. humidity 0...95% Temperature -20...50°C
    rel. humidity 0...95% Temperature -20...50°C Abs. pressure 0..10'000m 300...1'300 hPa
    external sensors UMB-bus & 2 AI I :0...20mA U:0..10V
    Measurement principle
    %RH : capacitive Temp : NTC
    %RH : capacitive Temp : NTC hPa : piezo
    see connected sensors!
    Accuracy:
    %RH : +/- 2% Temp : +/-0.3°C
    %RH : +/- 2% Temp : +/-0.3°C hPa : +/-0.5 hPa at 25°C
    see connected sensors!
    Resolution:
    %RH : 0.5% Temp : 0.1 °C
    %RH : 0.5% Temp : 0.1 °C hPa : 0.1 hPa
    Dimension:
    166x78x32 mm plastic housing
    166x78x32 mm plastic housing
    166x78x32 mm plastic housing
    Weight:
    approx. 250 gr
    approx. 250 gr
    approx. 250 gr
    LCD scree:
    specifi c 3 line segment LCD with status, Alarm, data, time, connection
    specifi c 3 line segment LCD with status, Alarm, data, time, connection
    specifi c 3 line segment LCD with status, Alarm, data, time, connection
    Power supply:
    4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option)
    4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option)
    4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option)
    Interfaces
    USB, LAN (ethernet TCP/IP), UMB-bus
    USB, LAN (ethernet TCP/IP), UMB-bus
    USB, LAN (ethernet TCP/IP), UMB-bus
    Memory:
    16 MB - 3'200'000 data points
    16 MB - 3'200'000 data points
    16 MB - 3'200'000 data points
    Meas. interval:
    10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
    10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
    10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
    Memory interval:
    1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
    1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
    1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
    Operation cond:
    -20...+50°C / 0....95%RH (no condensation) / 10'000m a.s.l.
    -20...+50°C / 0....95%RH (no condensation) / 10'000m a.s.l.
    -20...+50°C / 0....95%RH (no condensation) / 10'000m a.s.l.

    Efficient Data loggers with built-in or external humidity, temperature or pressure sensor, which can be used both autonomous as a battery-powered unit or integrated into a network.

    These analyzers are characterized by their diverse applicability, their high precision measurement and the recording of the desired climatic parameters. Therefore, an individual adaptation to the user’s needs is possible.

    Key features:

    • Possibility for room mapping with external sensors
    • Large data storage of 3,2 million data points
    • Large display with additional acoustic alerting
    • User-friendly software for visualizing, analyzing and exporting of the data
    • Possibility to connect to a LAN-network  
    DKSH-Novasina-Humidity-Temperature-Measurement-HygroMaxx
    HygroMaxx S
    HygroMaxx R
    HygroMaxx M
    Dimensions
    183 x 110 x 50 mm
    118 x 110 x 300 mm
    118 x 110 x 50 mm
    Measurement range humidity
    0 .... 100 % rH
    0 .... 100 % rH
    0 .... 100 % rH
    Measurement range temperature
    -20 ... +80°C / -4 ... + 176 °F
    -20 ... +80°C / -4 ... + 176 °F
    -20 ... +80°C / -4 ... + 176 °F
    Accuracy humidity standard
    +/- 3.0 % rH
    +/- 3.0 % rH
    +/- 3.0 % rH
    Accuracy humidity with factory calibration
    +/- 1.5 % rH with 3 point calibration (11..53..90% rH)
    +/- 1.5 % rH with 3 point calibration (11..53..90% rH)
    +/- 1.5 % rH with 3 point calibration (11..53..90% rH)
    Display resolution
    0.1 % rH 0.1°C / 0.1°F
    0.1 % rH 0.1°C / 0.1°F
    0.1 % rH 0.1°C / 0.1°F
    Reproducibility humidity
    +/- 1.0 % rH range : 10 ... 85% rH
    +/- 1.0 % rH range : 10 ... 85% rH
    +/- 1.0 % rH range : 10 ... 85% rH
    Reproducibility temperature
    +/- 0.1 °C range : 0 ... 60°C
    +/- 0.1 °C range : 0 ... 60°C
    +/- 0.1 °C range : 0 ... 60°C
    Operating temperature
    electronics : 0... +50°C sensor : -20 ... + 80°C
    electronics : 0... +50°C sensor : -20 ... + 80°C
    electronics : 0... +50°C sensor : -20 ... + 80°C
    Long term stability of rH measurement
    < +/- 0.5 % rH / year at max. chemical working concentration
    < +/- 0.5 % rH / year at max. chemical working concentration
    < +/- 0.5 % rH / year at max. chemical working concentration
    Power supply
    24 VDC +/- 25% In-Out without galvanic isolation
    24 VDC +/- 25% In-Out without galvanic isolation
    24 VDC +/- 25% In-Out without galvanic isolation
    Norm tests / storage conditions Electromagnetic compatibility
    EN 61326-1 / EN 61326 / A1
    EN 61326-1 / EN 61326 / A1
    EN 61326-1 / EN 61326 / A1
    IP-protection / protection norm
    IP 54 / EN 61010-1
    IP 54 / EN 61010-1
    IP 54 / EN 61010-1
    Storage temperature (device)
    5 .... 60 °C ( not condensing )
    5 .... 60 °C ( not condensing )
    5 .... 60 °C ( not condensing )
    Storage air humidity (device)
    5 .... 80% rH ( not condensing )
    5 .... 80% rH ( not condensing )
    5 .... 80% rH ( not condensing )

    The ideal Thermo-Hygrometer for measurements of relative air humidity and temperature in room or duct applications in the HVAC industry.

    A digital, capacitive humidity measuring element, combined with modern electronic-architecture, allows a multifunctional usage with high measurement precision and simple application.

    Key features:

    • Different mounting forms for wall and duct installation
    • Large, well laid-out display
    • Simple to configure and calibrate
    • Scalable, analogue signal: mA or V
    • User-friendly menu structure with password protection
    DKSH-Novasina-Humidity-Temperature-Measurement-StatMaxx
    StatMaxx S
    StatMaxx R
    StatMaxx M
    Dimensions
    183 x 110 x 50 mm
    118 x 110 x 300 mm
    118 x 110 x 50 mm
    Measurement range humidity
    0 .... 100 % rH
    0 .... 100 % rH
    0 .... 100 % rH
    Measurement range temperature
    -20 ... +80°C
    -20 ... +80°C
    -20 ... +80°C
    Accuracy humidity-standard
    +/- 3.0 % rH
    +/- 3.0 % rH
    +/- 3.0 % rH
    Accuracy humidity with factory calibration
    +/- 1.5 % rH with 3 point calibration (11..53..90% rH)
    +/- 1.5 % rH with 3 point calibration (11..53..90% rH)
    +/- 1.5 % rH with 3 point calibration (11..53..90% rH)
    Display resolution
    0.1 % rH 0.1°C / 0.1°F
    0.1 % rH 0.1°C / 0.1°F
    0.1 % rH 0.1°C / 0.1°F
    Reproducibility humidity
    +/- 1.0 % rH range : 10 ... 85% rH
    +/- 1.0 % rH range : 10 ... 85% rH
    +/- 1.0 % rH range : 10 ... 85% rH
    Reproducibility temperature
    +/- 0.1 °C range : 0 ... 60°C
    +/- 0.1 °C range : 0 ... 60°C
    +/- 0.1 °C range : 0 ... 60°C
    Operating temperature
    electronics : 0... +50°C sensor : -20 ... + 80°C
    electronics : 0... +50°C sensor : -20 ... + 80°C
    electronics : 0... +50°C sensor : -20 ... + 80°C
    Long term stability of rH measurement
    < +/- 0.5 % rH / year at max. chemical working concentration
    < +/- 0.5 % rH / year at max. chemical working concentration
    < +/- 0.5 % rH / year at max. chemical working concentration
    Power supply
    24 VDC +/- 20%
    24 VDC +/- 20%
    24 VDC +/- 20%
    Norm tests / storage conditions Electromagnetic compatibility
    EN 61326-1 / EN 61326 A1
    EN 61326-1 / EN 61326 A1
    EN 61326-1 / EN 61326 A1
    IP-protection / protection norm
    IP 54 / EN 61010-1
    IP 54 / EN 61010-1
    IP 54 / EN 61010-1
    Storage temperature (device)
    5 .... 60 °C ( not condensing )
    5 .... 60 °C ( not condensing )
    5 .... 60 °C ( not condensing )
    Storage air humidity (device)
    5 .... 80% rH ( not condensing )
    5 .... 80% rH ( not condensing )
    5 .... 80% rH ( not condensing )

    This Thermo-Hygrostat with integrated relay switch is particularly useful for monitoring, supervision and regulation tasks in HVAC applications.

    Different mounting forms for wall and duct installations allow a customized use of the StatMaxx.

    Key features:

    • Large and well laid-out display
    • Simple to configure and calibrate
    • Integrated switching contact with configurable switching threshold function
    • User-friendly menu structure with password protection
    DKSH-Novasina-Humidity-Temperature-Measurement-TempMaxx
    TempMaxx
    Dimensions
    183 x 110 x 50 mm
    Measurement range temp. measurement PT/Ni 100
    -50...+400°C 2-, 3- or 4-wire connection
    Measurement range temp. measurement PT 1'000
    -50...+400°C 2-, 3- or 4-wire connection
    Measurement range temp. measurement Ni 1'000
    -50...+200°C 2-, 3- or 4-wire connection
    Measurement range temp. measurement Beta Therm
    -20...+80°C +/- 0,2 K 2-wire connection
    Display resolution
    0.1°C / 0.1°F
    Sensor break detection
    YES (display): at 2...10V and 4..20 mA = per 0 VAC / 0 mA
    Repeatability temperature
    depending on probe according to DIN EN 60751 AA, A, B, 1/3B, C
    Operating temperature
    electronics : -10...+50°C sensor : -50...+400°C
    Long term stability of rH measurement
    < +/- 0.5 % rH / year at max. chemical working concentration
    Power supply
    18...35 (24 VDC +/- 25%) without galvanic isolation 50...100mA depending on initial condition
    Accuracy
    +/- 0.15% FS accuracy without sensor element over full measurement range
    Password protection
    YES 4-digit code for all settings
    Special funtions: Alarm function
    High, Low, Hysteresis, Delay, NC or NO (On/OFF)
    2-point control fuction
    Setpoint, Hysteresis, Delay, NC or NO (On/OFF)
    Norm tests/storage conditions: Electromagnetic compatibility
    IEC 61000-6-2 / IEC 61000-6-4 / EN 61000-6-2 / EN 61000-6-4
    IP-protection / CE-Norm
    IP 41 / EN 61010-1
    Storage temperature (device)
    5 .... 60 °C ( not condensing )
    Storage air humidity (device)
    5 .... 80% rH ( not condensing )

    Universal temperature transmitter with analogue output and relay switch especially developed for demanding HVAC applications.

    This analyzer is characterized by its possibility to connect with various temperature sensors. Further, it is simple to configure, to mount and to calibrate.

    Key features:

    • Connection with standard PT100, PT1000 and NTC sensors
    • Large and well laid-out display
    • Integrated switching contact with configurable switching threshold function
    • Scalable, analogue signal: mA or V
    • User-friendly menu structure with password protection
    • Agriculture
    • Biopharmaceutical and Biotechnology
    • Cosmetics & Personal Care
    • Education & Academics
    • Electronics
    • Food & Beverage
    • Optical
    • Pharmaceutical
    • Semiconductor, Solar & Electronics
    • Service
    • Textile
    • Cambodia
    • China
    • Korea
    • Laos
    • Myanmar
    • Taiwan
    Novasina AGSince its establishment more than 50 years ago, the company Novasina has specialised in the accurate measuring of air and material humidity. Novasina fully develops and produces precision measuring devices and includes always its long lasting know-how. We are proud of the “SWISS MADE” label, which guarantees our customers highest quality, innovation and longevity.
    [Humidity & Temperature Measurement, Novasin, Quantdat, nSens, ClimMate, DataLog, ClimaLog, HygroGuard, HygroMaxx, StatMaxx, TempMaxx]