Need support?

Please leave a message

×

The ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of samples in Serum, plasma and cell culture supernates

Contact us

Available models

Sample type

Serum, plasma and cell culture supernates

Cross reacts with

Human

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

3.9 pg/mL

Standard curve range

6.25-400 pg/ml

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations.
2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents.

This Human IL-1 beta ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. Calibration standards are included, allowing you to create a standard curve to determine sample concentrations by comparing their O.D. to the curve.

Sample type

Serum, plasma and cell culture supernates

Cross reacts with

Human

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

0.7 pg/mL

Standard curve range

1.56-100pg/ml

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations.
2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents.

This Human IL-6 ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. Calibration standards are included, enabling the creation of a standard curve for sample concentration determination by comparing their O.D. to the curve.

Sample type

Serum, plasma and cell culture supernates

Cross reacts with

Mouse

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

7.8 pg/mL

Standard curve range

15.6-1000 pg/ml

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations.
2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents.

This Mouse IL-1 beta ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. Included calibration standards enable the creation of a standard curve to determine Mouse IL-1 beta concentration by comparing sample O.D. to the curve.

Sample type

serum, plasma, cell culture supernatants, cell Lysates, tissue homogenates and other biological fluids.

Cross reacts with

Mouse

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

7.2 pg/mL

Standard curve range

15.6-1000 pg/ml

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations.
2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents.

This Mouse IL-6 ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.

Sample type

serum, plasma, cell culture supernates

Cross reacts with

Human

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

7.3 pg/mL

Standard curve range

15.6-1000 pg/ml

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

This Human IFN-gamma ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm using a spectrophotometer. Calibration standards included enable the creation of an optical density standard curve for determining Human IFN-gamma concentration by comparing sample O.D. to the curve.

Sample type

serum, plasma, cell culture supernates

Cross reacts with

Mouse

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

15.6 pg/mL

Standard curve range

31.2-2000 pg/mL

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

This Mouse IL-10 ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.

Sample type

serum, plasma, cell culture supernates

Cross reacts with

Mouse

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

6.5 pg/mL

Standard curve range

15.6-1000 pg/mL

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

This Mouse TNF-alpha ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.

Sample type

serum, plasma, cell culture supernates

Cross reacts with

Human

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

6.9 pg/mL

Standard curve range

15.6-1000 pg/ml

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations.
2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents.

This Human TNF-alpha ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.

Sample type

serum, plasma, cell culture supernates

Cross reacts with

Mouse

Storage instructions

Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month.

Sensitivity

3.9 pg/mL

Standard curve range

15.6-1000 pg/ml

Components

Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution

1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations.
2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents.

This Mouse Transforming Growth Factor Beta 1 (TGFb1) ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.

ABclonalBased in Massachusetts, ABclonal aims to improve the accuracy and precision of life science research for scientists around the world by providing high-quality, personalized biology research reagents and services. Our large catalog of off-the-shelf products can be customized to ensure you can have the antibodies, peptides, and proteins best suited to you.
[]