The integral XT process thermostats operate according to the flow principle with a cold oil blanket that allows the utilization of the entire temperature range through the use of a heat transfer medium. The electronically controlled, magnetic coupled pump can alter the pressure to adapt the flow rate to the relevant process requirements. The Integral XT models can be integrated easily in different process control systems using a wide selection of interface modules.
The process thermostats can be operated easily and intuitively using the detachable Command remote control with plain text menu guidance and graphic display of the temperature profile.
Technical Specifications
|
|
---|---|
Working temperature min.
|
-45°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
2.6L
|
Filling vol. expansion vessel
|
5.5 L
|
Heater power
|
3.50 kW
|
Cooling output at 20°C measured with ethanol
|
1.5 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-45°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
2.6 L
|
Filling vol. expansion vessel
|
5.5 L
|
Heater power
|
3.50 kW
|
Cooling output at 20°C measured with ethanol
|
2.10 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-80°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
4.00 kW
|
Cooling output at 20°C measured with ethanol
|
1.5 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-80°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
4.00 kW
|
Cooling output at 20°C measured with ethanol
|
2.0 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.10 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
3.50 kW
|
Cooling output at 20°C measured with ethanol
|
3.1 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.10 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-90°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
9.5 L
|
Filling vol. expansion vessel
|
17.4 L
|
Heater power
|
5.30 kW
|
Cooling output at 20°C measured with ethanol
|
4.4 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.10 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
5.30 kW
|
Cooling output at 20°C measured with ethanol
|
5.00 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
5.30 kW
|
Cooling output at 20°C measured with ethanol
|
5.00 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.10 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
5.30 kW
|
Cooling output at 20°C measured with ethanol
|
5.00 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
8.00 kW
|
Cooling output at 20°C measured with ethanol
|
6.70 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
5.30 kW
|
Cooling output at 20°C measured with ethanol
|
6.70 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.10 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
5 L
|
Filling vol. expansion vessel
|
6.7 L
|
Heater power
|
8.00 kW
|
Cooling output at 20°C measured with ethanol
|
9.00 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.10 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
9 L
|
Filling vol. expansion vessel
|
17.4 L
|
Heater power
|
10.60 kW
|
Cooling output at 20°C measured with ethanol
|
18.50 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.30 ±K
|
Pump pressure max.
|
5.8 bar
|
Pump flow max. (pressure)
|
90 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-90°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
10.50 L
|
Filling vol. expansion vessel
|
17.4 L
|
Heater power
|
8.00 kW
|
Cooling output at 20°C measured with ethanol
|
9.00 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
-50°C
|
Working temperature max.
|
220°C
|
Filling volume min.
|
9 L
|
Filling vol. expansion vessel
|
17.4 L
|
Heater power
|
16.00 kW
|
Cooling output at 20°C measured with ethanol
|
18.50 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.30 ±K
|
Pump pressure max.
|
5.8 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
80°C
|
Working temperature max.
|
320°C
|
Filling volume min.
|
2.6 L
|
Filling vol. expansion vessel
|
5.5 L
|
Heater power
|
3.50 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
30°C
|
Working temperature max.
|
320°C
|
Filling volume min.
|
2.6 L
|
Filling vol. expansion vessel
|
5.5 L
|
Heater power
|
3.50 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|
Technical Specifications
|
|
---|---|
Working temperature min.
|
80°C
|
Working temperature max.
|
320°C
|
Filling volume min.
|
2.6 L
|
Filling vol. expansion vessel
|
5.5 L
|
Heater power
|
8.00 kW
|
Interface(s)
|
RS-232/485
|
Temperature stability
|
0.05 ±K
|
Pump pressure max.
|
2.9 bar
|
Pump flow max. (pressure)
|
45 L/min
|