GLP Complianced Laboratory Freeze Dryers
TELSTAR laboratory freeze dryers are specially designed for meeting research and development phase freeze drying requirements in the increasingly demanding R&D centres in industry and academia. All Telstar laboratory freeze dryers are designed according to GLP principles to comply with the strictest international standards.The laboratory freeze dryer range covers from small table-top units to sophisticated pilot equipment.
50 years Experience is Freeze Drying
All Telstar freeze drying units are designed and constructed in accordance with the strictest international standards and a scrupulous test process is performed before dispatch to the customer. The quality of Telstar equipment plus a commitment to provide the best possible technical service, make TELSTAR a leader in the field of laboratory freeze dryers. Moreover, Telstar's experience in the freeze drying field, through an established in-house freeze drying laboratory, guarantees customers not only the choice of the most suitable unit but also expert advice on how it should be used.
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
8 (5 KG / 24 H)
| |
Condenser Temperature (°C)
|
< -55
| |
Number of Compressors
|
1
| |
Base Unit (KG)
|
65
| |
Total Power (kW)
|
1,1
| |
Compact and multipurpose freeze dryer with unbeatable capacity, designed for research and development field. Customizable with wide range of accessories to improve users' experiences. |
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
8 (6 KG / 24 H)
| |
Condenser Temperature (°C)
|
< -85
| |
Number of Compressors
|
2
| |
Base Unit (KG)
|
70
| |
Total Power (kW)
|
1,4
| |
Compact and multipurpose freeze dryer with unbeatable capacity, designed for research and development field. Customizable with wide range of accessories to improve users' experiences. |
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
8 (5 KG / 24 H)
| |
Condenser Temperature (°C)
|
< -55
| |
Number of Compressors
|
1
| |
Base Unit (KG)
|
65
| |
Total Power (kW)
|
1,1
| |
Extension of LyoQuest. The LyoQuest Plus allows automatic pressure control and shelves temperature programming. Auto-start up and automatic switch off module are included. |
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
8 (6 KG / 24 H)
| |
Condenser Temperature (°C)
|
< -85
| |
Number of Compressors
|
2
| |
Base Unit (KG)
|
70
| |
Total Power (kW)
|
1,4
| |
Extension of LyoQuest. The LyoQuest Plus allows automatic pressure control and shelves temperature programming. Auto-start up and automatic switch off module are included. |
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
16,5
| |
Condenser Temperature (°C)
|
< -55
| |
Number of Compressors
|
1
| |
Base Unit (KG)
|
170
| |
Total Power (kW)
|
2,8
| |
A flexible freezer dryer for simultaneous freeze drying of bottles, vials or bulk products through the connection of different manifold systems or a chamber. Suitable for research centres requiring greater freeze drying capacity. |
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
16,5
| |
Condenser Temperature (°C)
|
< -85
| |
Number of Compressors
|
2
| |
Base Unit (KG)
|
200
| |
Total Power (kW)
|
3,4
| |
A flexible freezer dryer for simultaneous freeze drying of bottles, vials or bulk products through the connection of different manifold systems or a chamber. Suitable for research centres requiring greater freeze drying capacity. |
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
22
| |
Condenser Temperature (°C)
|
< -55
| |
Number of Compressors
|
1
| |
Base Unit (KG)
|
190
| |
Total Power (kW)
|
3,2
| |
A flexible freezer dryer for simultaneous freeze drying of bottles, vials or bulk products through the connection of different manifold systems or a chamber. Suitable for research centres requiring greater freeze drying capacity. |
Technical Specifications
|
| |
---|---|---|
Ice Condenser Capacity (KG)
|
22
| |
Condenser Temperature (°C)
|
< -85
| |
Number of Compressors
|
2
| |
Base Unit (KG)
|
220
| |
Total Power (kW)
|
4,3
| |
A flexible freezer dryer for simultaneous freeze drying of bottles, vials or bulk products through the connection of different manifold systems or a chamber. Suitable for research centres requiring greater freeze drying capacity. |
Technical Specifications
|
| |
---|---|---|
Number of shelves (ud)
|
3 + 1
| |
Shelves Dimensions
|
- 338 x 450 mm (W x D)- 13 x 17 (inches)
| |
Useable shelf area
|
- 0.45 m2- 4.93 sq.ft
| |
Clearance
|
100 mm3.9 inches
| |
Shelf temperature range
|
- 60 to +80 °C
| |
Condenser Capacity
|
- 30 KG- 66 LB
| |
Condenser capacity in 24 h
|
- 18 KG- 39 LB
| |
Final Condenser Temperature ( °C)
|
< - 80
| |
Electric power (kW)
|
8
| |
Power supply (V/Hz)
|
- 230/1/50/60- Upgradeable under request
| |
Vacuum pump flow
|
- 12 m³/H- 5 cfm
| |
Weight
|
- 730 KG- 1609 LB
| |
Dimensions
|
- 1245 (W) * 1974 (H) * 818 (D) (mm)- 49 (W) * 77.7 (H) * 32.2 (D) (inches)
| |
One of the main new features of the LyoBeta Series freeze-dryers is the incorporation of a non-proprietary PLC, instead of the classic microprocessor, more commonly used in this type of equipment. This system, fully proven in the industrial models, guarantees maximum reliability and reproducibility in the process, in accordance with the principles of cGLP. |
Technical Specifications
|
| |
---|---|---|
Number of shelves (ud)
|
4 + 1
| |
Shelves Dimensions
|
- 338 x 450 mm (W x D)- 13 x 17 (inches)
| |
Useable shelf area
|
- 0.60 m2- 6.57 sq.ft
| |
Clearance
|
71 mm2.8 inches
| |
Shelf temperature range
|
- 60 to +80 °C
| |
Condenser Capacity
|
- 30 KG- 66 LB
| |
Condenser capacity in 24 h
|
- 18 KG- 39 LB
| |
Final Condenser Temperature ( °C)
|
< - 80
| |
Electric power (kW)
|
8
| |
Power supply (V/Hz)
|
- 230/1/50/60- Upgradeable under request
| |
Vacuum pump flow
|
- 12 m³/H- 5 cfm
| |
Weight
|
- 745 KG- 1642 LB
| |
Dimensions
|
- 1245 (W) * 1974 (H) * 818 (D) (mm)- 49 (W) * 77.7 (H) * 32.2 (D) (inches)
| |
One of the main new features of the LyoBeta Series freeze-dryers is the incorporation of a non-proprietary PLC, instead of the classic microprocessor, more commonly used in this type of equipment. This system, fully proven in the industrial models, guarantees maximum reliability and reproducibility in the process, in accordance with the principles of cGLP. |
Technical Specifications
|
| |
---|---|---|
Number of shelves (ud)
|
5 + 1
| |
Shelves Dimensions
|
- 338 x 450 mm (W x D)- 13 x 17 (inches)
| |
Useable shelf area
|
- 0.75 m2- 8.21 sq.ft
| |
Clearance
|
54 mm2.1 inches
| |
Shelf temperature range
|
- 60 to +80 °C
| |
Condenser Capacity
|
- 30 KG- 66 LB
| |
Condenser capacity in 24 h
|
- 18 KG- 39 LB
| |
Final Condenser Temperature ( °C)
|
< - 80
| |
Electric power (kW)
|
8
| |
Power supply (V/Hz)
|
- 230/1/50/60- Upgradeable under request
| |
Vacuum pump flow
|
- 12 m³/H- 5 cfm
| |
Weight
|
- 760 KG- 1675 LB
| |
Dimensions
|
- 1245 (W) * 1974 (H) * 818 (D) (mm)- 49 (W) * 77.7 (H) * 32.2 (D) (inches)
| |
One of the main new features of the LyoBeta Series freeze-dryers is the incorporation of a non-proprietary PLC, instead of the classic microprocessor, more commonly used in this type of equipment. This system, fully proven in the industrial models, guarantees maximum reliability and reproducibility in the process, in accordance with the principles of cGLP. |
Technical Specifications
|
| |
---|---|---|
Number of shelves (ud)
|
6 + 1
| |
Shelves Dimensions
|
- 338 x 450 mm (W x D)- 13 x 17 (inches)
| |
Useable shelf area
|
- 0.9 m2- 9.86 sq.ft
| |
Clearance
|
66 mm2.6 inches
| |
Shelf temperature range
|
- 60 to +80 °C
| |
Condenser Capacity
|
- 30 KG- 66 LB
| |
Condenser capacity in 24 h
|
- 24 KG- 52 LB
| |
Final Condenser Temperature ( °C)
|
< - 80
| |
Electric power (kW)
|
9
| |
Power supply (V/Hz)
|
- 230/III/50/60- Upgradeable under request
| |
Vacuum pump flow
|
- 12 m³/H- 5 cfm
| |
Weight
|
- 910 KG- 2010 LB
| |
Dimensions
|
- 1245 (W) * 1974 (H) * 818 (D) (mm)- 49 (W) * 77.7 (H) * 32.2 (D) (inches)
| |
One of the main new features of the LyoBeta Series freeze-dryers is the incorporation of a non-proprietary PLC, instead of the classic microprocessor, more commonly used in this type of equipment. This system, fully proven in the industrial models, guarantees maximum reliability and reproducibility in the process, in accordance with the principles of cGLP. |
Technical Specifications
|
| |
---|---|---|
Number of Shelves
|
2
| |
Shelf Dimensions (mm)
|
386(W) * 224 (D)
| |
Usable Shelf Area (m²)
|
0.18
| |
Shelf Temperature range (°C)
|
-55 to +70
| |
Condenser capacity (KG)
|
5.5
| |
Final Condenser temperature (°C)
|
< -85
| |
Weight (KG)
|
200
| |
Dimensions (mm)
|
944 * 755 * 630
| |
Benchtop freeze dryer with industrial performance. Highest freeze-drying performance with minimum footprint, occupying less space in research laboratories. |