Ensuring food product safety is critical in today's extended supply chains. Customers need peace of mind that they are consuming fresh and high-quality ingredients that have been analyzed using the latest food testing methods. At the same time, manufacturers need to deploy rapid microbiology testing equipment with fast, accurate and compliant laboratory methods for identification of microorganisms to optimize production and ensure profitability. To meet these challenges many food companies all over the world rely on CHEMUNEX® technology. The system offers an advanced solution for the rapid detection of microorganisms that enables to speed up product release and provide safe and fresh food products to customers.
The D-COUNT® system is an advanced analysis solution for the rapid detection of microorganisms. Rapid detection tests in microbiology enable greater efficiencies and enhanced capabilities in the lab.
Rapid microbiology testing with the D-COUNT® system improves quality assurance and production, overcoming the limits of classical microbiology that exist due to the growth rate of microorganisms on culture media.
The advanced solution for rapid testing helps to reduce production cycle times and inventories, as well as implement just-in-time manufacturing processes. It also minimizes the risks and costs associated with potential in-process contamination while continuing to guarantee and enhance the quality of products delivered to customers.
D-Count 25 | D-Count 50 | |||
---|---|---|---|---|
Dimensions | 1279 x 615 x 530 mm | 1535 x 600 x 530 mm | ||
Weight | 75 kg | 91 kg | ||
Electrical Specifications | Supply voltage | One phase with earth 100/240 VAC | One phase with earth 100/240 VAC | |
Supply frequency | 50/60 Hz | 50/60 Hz | ||
Input | 100 - 120/220 VAC, 50/60 Hz 25 W | 100 - 120/220 VAC, 50/60 Hz 350 W | ||
Fuse | Analyzer: 250 V T 3.15 AH (5 x 20 mm) (2x) SPU: 250 V T 5.0 A (5 x 20 mm) (2x) |
Analyzer: 250 V T 3.15 AH (5 x 20 mm) (2x) SPU: 250 V T 5.0 A (5 x 20 mm) (2x) |
||
Environmental Conditions* | Operating temperature | 18 to 28°C (64 to 82°F) With a mximum rate of temperature change at 5°C/hr (41°F/hr) |
18 to 28°C (64 to 82°F) With a mximum rate of temperature change at 5°C/hr (41°F/hr) |
|
Storage temperature | 2 to 45°C | 2 to 45°C | ||
Humidity | 30% to 80% relative humidity, non-condensing | 30% to 80% relative humidity, non-condensing | ||
Altitude | 3000 m (9900 ft) maximum | 3000 m (9900 ft) maximum | ||
Sound level | < 70 dB | < 70 dB | ||
Computer Specifications | Material Properties | Embedded computer running Windows 7 32 bit Touch Screen |
Embedded computer running Windows 7 32 bit Touch Screen |
|
*The instrument is designed for laboratory environmental conditions or better. Dust levels should be minimized although the instrument is well covered by shields and internal cabinetry to ensure adequate protection under the advised operational conditions. |