Need support?

Please leave a message

×

ST 243 Soxtec™

Safe operations with spark proof hot plate. Save time with batch handling tools. Compatible with the SoxCap hydrolysis solution for total fat analysis.

ST 255 Soxtec™

Semi automated, flexible extraction system suitable for a wide range of applications in the food, feed, environmental and other industrial segments.

Soxtec™ 8000

The Soxtec™ 8000 extraction unit is a fully automated system for fast and safe extraction of soluble matter from a wide range of matrices. It performs the four extraction steps boiling, rinsing, solvent recovery and auto-shut down, fully unattended. Just load, start and walk away.

The Soxtec™ series

ST 243 Soxtec™ ST 255 Soxtec™ Soxtec™ 8000
Levels of automation Manual Semi automated Fully automated
Positions 6 6 6 - 12
Capacity/day 30 - 36 samples 30 - 36 samples 42/86 samples
Solvent volume 40 - 50 ml 70 - 90 ml 40 - 110 ml
Thimble diameter 26 mm 26, 33 mm 26, 33 mm
Compatible with hydrolysis unit SC 247 SoxCap™ with mini capsules Hydrotec™ 8000 and SC 247 SoxCap™ Hydrotec™ 8000 and SC 247 SoxCap™
Value Safe operations with spark proof hot plate. Save time with batch handling tools. Compatible with the SoxCap hydrolysis solution for total fat analysis. Safe operations with spark proof hot plate. Save time with batch handling tools. Compatible with hydrolysis solutions for total fat analysis. First fully automated Soxhlet system. Improving throughput at a lower cost. Reducing risk in fat analysis. Batch handling tools for easy operation.
Sample type Feed, feed ingredients, forage, pet food, food, food ingredients, grain, cereal, oil seeds, DDGS, meat, meat products, fish, fish products, dairy products, environmental products (e.g. soil, sludge, waste water) and other industry products (paper pulp, textiles, rubber, tobacco, fertilizer, detergents, plastic and more). Feed, feed ingredients, forage, pet food, food, food ingredients, grain, cereal, oil seeds, DDGS, meat, meat products, fish, fish products, dairy products, environmental products (e.g. soil, sludge, waste water) and other industry products (paper pulp, textiles, rubber, tobacco, fertilizer, detergents, plastic and more). Feed, feed ingredients, forage, pet food, food, food ingredients, grain, cereal, oil seeds, DDGS, meat, meat products, fish, fish products, dairy products, environmental products, (e.g. soil, sludge, waste water) and other industry products (paper pulp, textiles, rubber, tobacco, fertilizer, detergents, plastic and more).
Parameters Crude fat, total fat and extractable matter. Crude fat, total fat and extractable matter. Crude fat, total fat and extractable matter.

Available models

Technical specifications
Performance data at 230 V
Extraction time
Typically 45 – 60 min
Solvent volume
40 – 50 ml
Sample size
0.5 – 3 g depending on sample type 0.5 – 2 g (for total fat)
Capacity/batch
6 positions
Capacity/day
36 samples
Temperature range
0 – 285 °C
Measuring range
0.1 – 100 %
Reproducibility
1% rel. or better (5 – 100% fat)
Solvent recovery
Typically 80 %
Accuracy
According to officially approved methods
Installation Requirements
Power supply
230 V, 50-60 Hz, 115 V, 50-60 Hz
Power consumption
1250 W
Water consumption
2/l min
Weight
Extraction unit: 30 kg Control unit: 3 kg
Dimensions (W x D x H)
Extraction unit: 570 × 350 × 580 mm Control unit: 280 × 230 × 190 mm
Ventilation
Fume hood min. airflow 0,5 m/s (inter locked)

Key features:

  • Batch handling tools and accessories

Overall laboratory efficiency is further improved by the purpose-developed handling tools delivered with the Soxtec™ system. The tools for simple batch-wise sample handling save time, simplify usage and minimise risk of operator error. There is no longer any need for manual handling of thimbles or hot extraction cups.

Technical specifications
Performance data at 230 V
Extraction time
Typically 45 – 60 min
Solvent volume
70 – 90 ml depending on cup type
Sample size
0.5 – 3 g depending on sample type 0.5 – 2 g (for total fat)
Capacity/batch
6 positions
Capacity/day
36 samples
Temperature range
0 – 285 °C
Measuring range
0.1 – 100 %
Reproducibility
1% rel. Or better (5 – 100% fat)
Solvent recovery
Typically 80 %
Accuracy
According to officially approved methods
Installation Requirements
Power supply
230 V, 50-60 Hz
Power consumption
1550 W
Water consumption
2/l min
Weight net
Extraction unit: 30 kg Control unit: 3 kg
Dimensions (W x D x H)
Extraction unit: 600 × 380 × 580 mm Control unit: 310 × 240 × 160 mm
Ventilation
Fume hood min. Airflow 0,5 m/s (inter locked)

Key features:

  • Accessories

Soxtec systems has an extensive range of accessories with glass and aluminium cups and thimbles in different sizes to fit individual laboratory needs and applications.
 

  • Batch handling tools and accessories

Overall laboratory efficiency is further improved by the purpose-developed handling tools delivered with the Soxtec™ system. The tools for simple batch-wise sample handling save time, simplify usage and minimise risk of operator error. There is no longer any need for manual handling of thimbles or hot extraction cups.
 

  • Total fat determination

Compatible with Hydrotec™ 8000 Hydrolysis unit for total fat determination.

Technical specifications
Performance data at 230 V
Extraction time
Typically 45 – 60 min
Solvent volume
40 – 110 ml depending on cup type
Sample size
0.5 – 3 g depending on sample type 0.5 – 2 g (for total fat)
Capacity/batch
6/12 positions
Capacity/day
42/84 samples
Temperature range
0 – 285 °C
Measuring range
0.1 – 100 %
Reproducibility
1% rel. Or better (5 – 100% fat)
Solvent Recovery
Typically 80 %
Accuracy
According to officially approved methods
Installation requirements
Power supply
200 – 240 V 50 – 60 Hz
Power consumption
1500 W (120 VAC version) 1800 W (230 VAC version)
Water consumption
2 l/min < 25°C minimum flow
Weight net
Extraction unit: 35 kg Control unit: 4 kg
Dimensions (W×D×H)
Extraction unit: 640 × 350 × 630 mm Control unit: 280 × 200 × 190 mm

Key features:

  • Flexible operation

The Soxtec™ 8000 total fat solution helps you respond to the demands of your customers, for example, you can do total or crude fat analysis or both. It’s easy to increase capacity according to customer requirements with up to 12 position hydrolysis and six position extraction that is expandable to 12, all with individual hotplate control.
 

  • Simplified process

This unique patented Hydrocap™ filter contains the sample from the initial weighing, through hydrolysis to final extraction; avoiding sample transfer errors. It is a fully automated system that performs automated acid hydrolysis and Randall improved Soxhlet extraction in one integrated process.
 

  • Secure solvent dispensing & recovery
  • Accessories

Soxtec™ systems has an extensive range of accessories with glass and aluminium cups and thimbles in different sizes to fit individual laboratory needs and applications.

ST 243 Soxtec™ solvent extraction system

ST 255 Soxtec™ solvent extraction system

How to do crude fat analysis with the Soxtec 8000 system

  • Biopharmaceutical and Biotechnology
  • Chemical
  • Education & Academics
  • Environmental
  • Food & Beverage
  • Pharmaceutical
Foss Analytical

FOSS creates end-to-end solutions that secure and improve food quality. From raw material to finished product. Our analysis instruments refine measurements into information management that enables businesses to run intelligent data-driven productions with less waste and bigger yields. Controlling cost and quality across all sectors and value chains, we help food and agricultural producers limit the number of human errors, scale their business faster and reduce manual labor as well as labor costs. We call it analytics beyond measure.

We cover these food and agricultural industries: Dairy, Feed and Forage, Grain, Flour Milling & Oilseed Processing, Laboratories, Meat, Raw Milk Testing and Wine.

Over the last 60 years, we have made it our business to define the standard of analytical solutions for the food and agricultural industry. We pioneered advanced analysis for the challenging production environments in the 1960’s, and we were the first to integrate chemical composition analysis in process lines. Now our resolve and ambition have also made us the international benchmark in the field of chemometrics and real time analytics.

[]