Your samples are delicate, often irreplaceable. You depend on consistent performance from your equipment throughout your work, from sample preparation to storage.
Thermo Scientific Forma Environmental Chambers feature proven technology for outstanding temperature uniformity and stability.
Stability Chambers
Stability Chambers provide a controlled temperature and humidity environment. They are perfect for stability tests, e.g. in Pharma or packaging. Other applications include environmental testing or controlled storage.
Reach-in Chambers
Reach-in Chambers are heat only and provide a controlled temperature environment above the ambient temperature. Typical applications are microbiological incubation, or controlled storage. High volumes of samples can be incubated, tested or stored.
Vertical Light Chambers
Vertical Light Chambers are perfect for light stability testing, plant growth or animal hatching. The samples are exposed to the light from above, temperature + humidity can be controlled. Choose from various different light modules to address the specific application.
Stability Chambers | Reach-in Chambers | Vertical Light Chambers | |
---|---|---|---|
Description | Meets compliance standards for ICH, FDA, TAPPI, ASTM or national testing standards | Focused on elevated temperature-only segments of drug stability and incubation | Meet ICH guidelines for photo stability testing Q1B Simulate gradual transitions from day to night, suitable for plant and insect growth |
Termperature Range | 0°C to 60°C | 5°C above ambient to 60°C |
10°C to 50°C with light on |
Relative Humidity | Above ambient to 95% @ 37°C |
NA | NA / Above ambient to 75% @ 30°C |
CO2 | Optional | NA | NA |
Size (Cu.Ft/L) | 29 / 821 | 11 / 311 | 29 / 821 | 29 / 821. | 11 / 311 |
|
Large Stability Chamber
|
Small Stability Chamber
|
---|---|---|
Size
|
821L
|
311L
|
Exterior (W x H x D)
|
965 x 2248 x 813mm
38.00 x 88.50 x 32.00 in.
|
965 x 1308 x 813mm
38.00 x 51.50 x 32.00 in.
|
Interior (W x H x D)
|
787 x 1524 x 686mm
31.00 x 60.00 x 27.00 in.
|
787 x 609 x 686mm
31.00 x 24.00 x 27.00 in.
|
Net weight
|
347kg / 765 lbs
|
261kg / 575 lbs
|
Shipping weight
|
472kg / 1040 lbs
|
325kg / 715 lbs
|
Temperature
|
|
|
Temperature range
|
0°C to 60°C (32°F to 140°F)
|
0°C to 60°C (32°F to 140°F)
|
Controller, sensor
|
Watlow Microprocessor - PID, with RTD sensor
|
Watlow Microprocessor - PID, with RTD sensor
|
Display
|
Digital dual LED, 0.1°C steps readability & setability
|
Digital dual LED, 0.1°C steps readability & setability
|
Humidity
|
|
|
Water consumption / specification
|
Max. 12L per day / 3 gal per day;
demineralised water, resistance: 0.5 - 1 MΩ cm
|
Max. 12L per day / 3 gal per day;
demineralised water, resistance: 0.5 - 1 MΩ cm
|
Relative humidity range
|
Above ambient to 95% @ 37°C (98.6°F) ±5.0% RH
|
Above ambient to 95% @ 37°C (98.6°F) ±5.0% RH
|
Electrical
|
|
|
Voltage
|
230V, 50/60Hz, 15.0 Amps
|
230V, 50/60Hz, 15.0 Amps
|
Plug
|
NEMA 14-20P
|
NEMA 14-20P
|
The stability chambers meet International Conference on Harmonization (ICH) guidelines for drug substance and product storage testing. The units are ideal for drug stability studies, shelf-life testing for packaged products, and insect and other large-scale biological research.
|
Large Stability Chamber
|
---|---|
Size
|
29 cu. ft.
|
Physical properties
|
821L Reach-In Incubated Chamber with heating only
|
Exterior (W x H x D)
|
965 x 2032 x 833mm
38.00 x 80.00 x 33.00 in.
|
Interior (W x H x D)
|
787 x 1524 x 686mm
31.00 x 60.00 x 27.00 in.
|
Net weight
|
227kg / 500 lbs
|
Shipping weight
|
300kg / 660 lbs
|
Temperature
|
|
Temperature range
|
5°C above ambient to 60°C
|
Controller, sensor
|
Environ-Scan - PID, with RTD sensor
|
Display
|
Digital dual LED, 0.1°C steps readability & setability
|
Electrical
|
|
Voltage
|
230V, 50/60Hz, 5.0 Amps
|
Plug
|
230V: CEE 7/7
|
Power switch
|
2-Pole
|
Interior convenience receptacles
|
230W max., for standard EU CEE7/7
|
Reach-in incubator for elevated temperature applications
Reach-In Refrigerated incubator broad temperature range covers incubation, testing and storage applications that require temperature control.
Reach-in chambers for elevated application temperatures
Choose from various door options:
Optional Cell Roll System
An optional cell roll system allows extensive production of monolayer cell cultures in standard roller culture vessels. This helps improved oxygenation and exposure of the cells to the media growth area. Combined uniform temperature control and continuous, gentile rotation provided by the cell roll system create the ideal conditions to help increase culture yields.
|
Vertical Light Large
Stability Chamber
|
Vertical Light Small
Stability Chamber
|
---|---|---|
Size
|
821L
|
311L
|
Heating
|
✓
|
✓
|
Cooling
|
✓
|
✓
|
Light Option
|
✓
|
✓
|
Humidity
|
✓
|
✓
|
Set Light and Temperature - No Humidity Control
|
|
|
Max. # of light modules
|
3
|
2
|
Temp. range with light
switched on
|
25°C to 50°C
(68°F to 122°F)
|
10°C to 50°C
(50°F to 122°F)
|
Display
|
Digital dual LED, 0.1°C steps readability & setability
|
Digital dual LED, 0.1°C steps readability & setability
|
Set Light and Temperature - Humidity
|
|
|
Max # of light modules
|
2
|
2
|
Relative humidity range
|
Above ambient to 75% @ 50°C (122°F)
|
Above ambient to 75% @ 50°C (122°F)
|
Humidity stability
|
≤ ±5% RH
|
≤ ±5% RH
|
Temperature range
|
15°C to 50°C
(59°F to 122°F)
|
10°C to 50°C
(50°F to 122°F)
|
Vertical Light Chambers address a variety of applications that require sample exposure with light, along with temperature control and humidity.
Address applications under optimal conditions with light choices. Wide light distribution is achieved with 7 fluorescent light bulbs.
The Thermo Scientific Directed Airflow System versus a top-to-bottom, undirected airflow design. The directed airflow minimizes the risk of product desiccation and loss, and wasted time and money due to poor temperature uniformity and recovery. The horizontal airflow of Thermo ensures great temperature uniformity and stability values - even with many samples on the shelves.
The chart illustrates the maximum and minimum attainable humidity within the cabinet at a given set temperature under the following nominal conditions: refrigeration on, defrost off, no wet bulb recorder, no air exchange, set for 22.2°C (72°F) and 50% RH ambient. Optional heatless dryer is available for lower humidity levels.