The Stand Alone Degassers are designed for use alongside your fluidic system. Simply plug in the unit and route your fluids through the degasser for consistent gas free fluids.
Length (in)
|
10.35
|
---|---|
Pressure Rating Max (psi)
|
70
|
Tubing ID (in)
|
0.045
|
Tubing ID (mm)
|
1.143
|
Power Requirements
|
100-240V AC 1A 50 to 60hz
|
Recommended Flow Rate (ml/min)
|
2
|
Membrane Type
|
Teflon™ AF
|
Internal Volume Per Channel uL
|
480
|
Wetted Materials
|
Teflon™ AF, Teflon™ FEP, PEEK and Glass-filled PPS (Polyphenylene Sulfide)
|
Vacuum Flow Path Materials
|
303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
|
Liquid Connections
|
¼-28 UNF
|
Expected Lifetime
|
>5 years (continuous run @ 60 RPM)
|
Width (in)
|
2.87
|
Height (in)
|
5.17
|
Stand Alone Vacuum Degasser Systems are specifically designed for HPLC. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 40mL/min. Select the "GPC" version for applications using hexanes.
Length (in)
|
10.35
|
---|---|
Tubing ID (in)
|
0.045
|
Tubing ID (mm)
|
1.143
|
Power Requirements
|
100-240V AC 1A 50 to 60hz
|
Recommended Flow Rate (ml/min)
|
2
|
Membrane Type
|
Teflon™ AF
|
Internal Volume Per Channel uL
|
480
|
Wetted Materials
|
Teflon™ AF, Teflon™ FEP, PEEK and Glass-filled PPS (Polyphenylene Sulfide), Stainless Steel
|
Vacuum Flow Path Materials
|
303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
|
Liquid Connections
|
¼-28 UNF
|
Expected Lifetime
|
>5 years (continuous run @ 60 RPM)
|
Width (in)
|
2.87
|
Height (in)
|
5.17
|
Stand Alone Vacuum Degasser Systems are specifically designed for HPLC. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 40mL/min. Select the "GPC" version for applications using hexanes.
Length (in)
|
10.35
|
---|---|
Pressure Rating Max (psi)
|
70
|
Tubing ID (in)
|
0.075
|
Power Requirements
|
100-240V AC 1A 50 to 60hz
|
Membrane Type
|
Teflon™ AF
|
Wetted Materials
|
Teflon™ AF, Teflon™ FEP, PEEK and Glass-filled PPS (Polyphenylene Sulfide)
|
Vacuum Flow Path Materials
|
303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
|
Liquid Connections
|
¼-28 UNF
|
Expected Lifetime
|
>5 years (continuous run @ 60 RPM)
|
Width (in)
|
2.87
|
Height (in)
|
5.17
|
Stand alone Vacuum Degasser Systems are specifically designed for HPLC. The Preparative systems are designed for flow rates up to 40ml/min. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 40mL/min. Select the "GPC" version for applications using hexanes.